Hi,
we have T620 thinclints running ThinPro 61.
Customers need to use Datev midentity usb smartcard readers on a windows terminal server (Windows Server 2012 R2) via rdp.
The device shows up in the usb-manager, which is configured to redirect all device to rdp connections.
Smart Cards are redirected via the class setting.
The device is sold by Kobil Systems GmbH (https://www.kobil.com/)
Link to the device in GERMAN
https://www.datev.de/web/de/datev-shop/it-loesungen-und-security/datev-midentity-compact/
# lsusb |grep Kobil
Bus 005 Device 003: ID 0d46:3014 Kobil Systems GmbH
# pcsc_scan -n
PC/SC device scanner
V 1.4.22 (c) 2001-2011, Ludovic Rousseau <ludovic.rousseau@free.fr>
Compiled with PC/SC lite version: 1.8.10
Using reader plug'n play mechanism
Scanning present readers...
0: KOBIL Systems Smart Token (NE134209584) 00 00
Wed May 17 11:04:06 2017
Reader 0: KOBIL Systems Smart Token (NE134209584) 00 00
Card state: Card inserted,
ATR: 3B BF 96 00 81 31 FE 5D 00 64 84 11 24 00 31 C0 73 F7 01 D0 00 90 00 DB
Starting a rdp connection via the Connection manager doesn't redirect the device, though.
Manually runnging xfreerdp with the /smartcard: option works.
How do I turn that option on via the connection manager?
Thanks in advance,
Michael